Syringe Pump Features
• Compact , lightweight & rugged design
• High accuracy performance ensures precise delivery of drug
• Supports 5, 10, 20, 30, 50 (60) ml syringes
• Precise occlusion pressure settings with anti bolus safety
• Special night mode feature given for soothing operation at night
• Real time display and more than 80,000 history records
• Could transfer stackable pumps with pump stackability
• Additional line disconnection alarm for patient safety
• Upgradable to PCA (Patient Control Analgesia)
• Dual audio o/p selection: Buzzer or Speaker
• Drug library with more than 100 no. of drugs
• Dynamic Pressure Surveillance (DPS)
• Adjustable alarm volume level
• Diagnostic screen for parameter surveillance
• Automatic Syringe size detection
Highlights




| Infusion Mode | Rate mode |
| Time mode | |
| Micro infusion mode | |
| Body weight mode | |
| Ramp up/Ramp down mode | |
| Sequential mode | |
| PCA mode (Optional) | |
| Applicable Syringe | Disposable sterile syringes: 50/60, 30, 20, 10,5 & 2/3 mL of more than 16 brands or can be customized |
| Syringe Accuracy | ±1% after syringe calibration for other than standard brand syringe |
| Infusion Rate | 2 ml, 5 ml syringe 0.01-120 ml/h |
| 10ml syringe 0.01-300 ml/h | |
| 20ml syringe 0.01-600 ml/h | |
| 50/60ml syringe 0.011800 ml/h | |
| Volume to be Infused | 0~999.99 ml |
| Volume Infused | 0~999.99 ml |
| KVO Rate | 0.01-10 ml/h, default 0.1ml/h, automatic or manual changeover |
| Specific Functions | Automatic/Manual bolus: 0.10-1800 ml/h (depending on syringe size) |
| More than 80,000 event logs Multiple pumps stackable function | |
| Adjustable alarm volume level | |
| Nurse call interface & potential free contact for nurse room (optional) | |
| Optional PCA (Patient Controlled Analgesia) | |
| Special Night mode feature | |
| Audible and Visual Alarm | Syringe disengaged, Occlusion Pre alarm, occlusion, Patient IV line |
| disconnection, syringe empty & syringe near end, VTBI near end and VTBI done, low battery, battery empty, motor error, Syringe Flange | |
| Out, Drive disengaged alarm, mains failure | |
| Power Supply | AC: 100-230V 50/60Hz; DC: 9V ±0.1V, 1.5 amps |
| Safety Classification | Class I, CF |
| Dimension | 310 x 110 x 145 mm (length x height x breadth) |
| Net Weight | @1.8 Kg |
| Occlusion Pressure | Multiple levels programmable of occlusion pressure settings as per user’s choice. |
| Battery | Li-ion 7.4V 2500mAh, could run more than 8 hours at 10ml/h or more if demanded. |
| Battery Charging Time | 8-10 hours |
| Operating Conditions | Temperature: 5°C-40 °C, Relative humidity 10-95%, Atmosphere |
| pressure: 86-106Κρα | |
| Interface | RS485/RS232 |
| Standards | EN60601-1, EN60601-2-24, EN60601-1-4, IEC LEVEL 3 (IPX 4), ISO13485, CDSCO |