Simtek-Infutek 405 series syringe driver popularly also known as syringe Infusion Pump is a basic equipment for :
Intensive care units (ICU), operating theaters, emergency, anaesthesiology, cardiology, neonatology, paediatrics, oncology and general hospital wards. Ideally suited for administration of anti-cancer drugs, oxytocics, chemotherapy medication, anaesthesia & life saving drugs. Infutek 405 is indispensable wherever high-potency drugs are to be precisely delivered at controlled flow rates over an extended period.
Highlights
• Convenience of Front Loading.
• Utility of Stacking.
• Drug Library.
• Allows at a Glance Visualisation of Drug Names, Volume Infused, Infusion Time & Flow Rate On LCD/LED Displays.
• Body Weight Rate Calculation.
• Bolus with Safety Time Lock.
• Adjustable Target Volume With Pre Alarm.
• Programmable to Accept Any Brand of Syringe.
• Automatic Rate Calculation with Volume and Time Limit.
• Upgradable to Double Loop PCA (Optional).
• Impact Resistant Strong Cabinet to Protect the Equipment During Accidental Mechanical Impact.
SYRINGE | 10,20,30, 50/60 ML,5ML (Optional), 100 ML. (Optional) |
FRONT LOADING OF SYRINGE | Syringe size is automatically detected |
ACCEPTABLE SYRINGES | All available standard brands of syringes. Custom Programmable to any brand Syringe. |
FLOW RATE RANGE | 0.1-999.9m/Hr (Depending on syringe size) |
INFUSED VOLUME RANGE | 0.1-999.9ml |
BOLUS RATE & VOLUME | 300-999.9ml/hr (Depending on syringe size), Volume is Programmable by user |
BOLUS INTERVAL | A minimum interval of time can be preset between two Bolus dose to avoid accidental over infusion, 1 min to 24 Hrs. |
PURGE FACILITY | |
KVO | To Prevent Needle Clogging With Programmable Kvo Rate |
OCCLUSION | Low, Medium, High Levels |
PUMP STACKING | Multiple Pump Stacking with Normal or Optional Single Power Cord. Facility of Stacking of 2-3 Pumps with built in Stacking Clips, ensures more useful group application & in & portability around the hospital premises |
BODY WEIGHT MODE ( Optional ) | Delivery rate is calculated Automatically based on Volume & time preselection or on values entered for patient body weight with drug parameters. |
ALARMS Invalid | Occlusion, End of syringe, Low Battery, Syringe displaced, No Syringe, Wrong Syringe, Pre Alarm for END, rate, target Volume, Target Time, Target volume Pre-alarm, Mains Failure Alarm. |
ACCURACY | Volume: +/-1%, Time:+/-1% |
TIME LIMIT | Time from 00:01 To 23:59 (hramin) or more specially demanded |
VOLUME LIMITS | From 0.1ml to capacity of the syringe |
POWER | 220 VAC, +/-10%, 50/60 Hz 12VA |
BATTERY TYPE | Ni Mh. 12V. 1300 mA/Hr |
BATTERY BACK-UP | 5-6 Hrs (Typ.)@5ml/Hr Or more if specially demanded |
BATTERY RECHARGING | 20 Hrs. For Full Charging |
STANDARDS | Tested as per IEC 60601.1 60601-1-2 60601-2-24 |
DISPLAY | Premium look with exclusive Blue Color Display (Only In infutak 405 Ex ) |
RS485/RS232 PORT | For Computer Interface Central Monitoring Station (Only In infutak 405 Ex ) |
PCA (Optional) | Upgradable to PCA With Double loop safety for PCA Dose and time ( Only In infutak 405 Ex) |